Alloysafe.com

Skip to Main Content »

Search Site

Category Navigation:

You're currently on:

Automatic Shut-Off Valve ASOV-14CW

Double click on above image to view full picture

Zoom Out
Zoom In

Automatic Shut-Off Valve ASOV-14CW


Email to a Friend

Be the first to review this product

Availability: In stock.

$12.99
Add Items to Cart Add to Cart
OR

Quick Overview

Automatic Shut-Off Valve ASOV-14CW is a replacement part for a standard residential Reverse Osmosis (RO) System. The ASOV (Auto Shut Off Valve) is a key component that is used in standard Reverse Osmosis (RO) based Point-Of-Use (POU) drinking water treatment systems. The device saves as much as 15,000 Gallons of water per year by shutting off the water once your tank is full. It has been tested and certified by NSF International under NSF/ANSI Standard 58.

Automatic Shut-Off Valve ASOV-14CW is manufactured with NSF listed materials. It uses a diaphragm between the feed water and treated water to control the flow of feed water into the treatment system. The product is designed to shut off at 65% of supply line pressure. This means that the ASO Valve will shut off production, when the tank pressure reaches around 65% of the incoming line pressure.
Automatic Shut-Off Valve ASOV-14CW is a replacement part for a standard residential Reverse Osmosis (RO) System. The ASOV (Auto Shut Off Valve) is a key component that is used in standard Reverse Osmosis (RO) based Point-Of-Use (POU) drinking water treatment systems. The device saves as much as 15,000 Gallons of water per year by shutting off the water once your tank is full. It has been tested and certified by NSF International under NSF/ANSI Standard 58.

Automatic Shut-Off Valve ASOV-14CW is manufactured with NSF listed materials. It uses a diaphragm between the feed water and treated water to control the flow of feed water into the treatment system. The product is designed to shut off at 65% of supply line pressure. This means that the ASO Valve will shut off production, when the tank pressure reaches around 65% of the incoming line pressure.
Automatic Shut-Off Valve Specs:
Operating Pressure: 30-100 PSI
Operating Temperature: 120° F (50° C)
Materials of Construction:
• Body: Polypropylene
• Diaphragm: EPDM
• Screw: SS 304
Tested and Certified by NSF International to ANSI/NSF Standard 42 for material requirements only.
NSF STANDARD 58 CERTIFIED STRUCTURAL TESTING:
• 300 PSI HYDROSTATIC PRESSURE TESTING
• 400 PSI BURST PRESSURE TESTING
• 100,000 CYCLE TESTING FROM 0-150 PSI
NSF STANDARD 58 CERTIFIED PERFORMANCE TESTING:
• 20,000 CYCLE TESTING TO STIMULATE 10 YEARS OF USE.
Use ASOV-14CW in place of:
ASOV-14CB, ASOV-14QW, ASOV-14QB, ASV-14, ASV-14C, ASV-14Q, PWS392W, PWS592Q, ASV-2000W, ASV-100JG, ASV-100JACO
Automatic Shut-Off Valve Instructions (Scroll Down for Diagram):

The "in & out" markings are on the top of the valve. The top side of the valve is the high pressure side and the bottom side is the low pressure side.

1. Insert the tube feeding the membrane inlet into the ASOV IN/OUT fittings:

a) Insert the tube from the PREFILTER Outlet into the "IN" fitting .

b) Insert the opposite tube end that feeds the Membrane INLET into the "OUT" fitting . NOTE: The "IN & OUT" markings are on the screw side of the valve - THIS IS THE HIGH PRESSURE FEED SIDE.

2. Insert the tube feeding the tank from the Product Water port of the membrane housing:

a) Locate the Product Water outlet from the membrane housing (on the end w/ 2 ports: center is Product water, side port is Rinse/Drain).

b) Insert the Product water tube from the membrane housing into either "Tank" fitting of the valve (ie Low Pressure side).

c) Insert the opposite tube end that feeds the Tank into the other "Tank" fitting of the valve.

How the Automatic Shut-Off Valve Works:

The valve automatically shuts off production when the tank pressure reaches approximately 65% of the incoming line pressure to indicate the tank is full.

The ASO valve saves thousands of gallons of water. Reverse Osmosis Systems without an Automatic Shut-Off valve continually send rinse water to the drain even when the tank is full.

Automatic Shut-Off Valve Example Process:

Feed water goes through a set of three pre filters (Sediment filter, Carbon filter, Carbon filter), passes through the ASOV, and then goes to the RO membrane to produce RO water.

The RO water passes through the system to be stored in the water tank. When the tank fills with RO water and the tank pressure reaches 40 psi, the back pressure will reverse the ASOV diaphragm and will shut off due to the pressure differential.

When the RO water end pressure is greater than the Feed water pressure, it causes the piston to move downward and shut off the in and out channel.

When the ASOV In and Out channel shuts off, the system will not produce any RO water.

Product Tags

Add Your Tags:
Use spaces to separate tags. Use single quotes (') for phrases.
 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.